Learning center / Acoustics by building type / Warehouse and workshop

How many acoustic panels does a warehouse and workshop need?

A worked Sabine calculation for a typical workshop, with panel counts for small, typical and large rooms.

2 minute read · Updated Nov 2026

The number of panels depends on three things: the room's volume, how much its surfaces already absorb, and how short you want the echo to be. Here is the calculation for a typical workshop, step by step.

Step 1: the room

A typical workshop of 100 × 60 ft with a 24 ft ceiling has a volume of about 144,000 ft³. With hard and bare surfaces (tile, concrete, glass and little soft furniture), its echo time is about 7.18 seconds. The target for workshops is 1.50 seconds.

Step 2: how much absorption is missing

Sabine's formula says RT60 = 0.161 × V ÷ A, with V in cubic meters and A, the total absorption, in square-meter sabins. To reach 1.50 s, the room needs about 4,711 ft² sabins of absorption in total. It already has about 984 from its surfaces, so the panels must add the rest.

Step 3: what one panel adds

A 96 × 24 in rectangular baffle, 2 in thick has about 16.0 ft² of face. At NRC 1.00, and allowing for the surface it covers, it adds about 22.8 sabins, including the extra absorption from its back face and edges when it hangs in the air.

Step 4: the answer

About 164 panels bring the room from 7.18 s to 1.50 s.

Same room, same panel size, different thickness.
ThicknessNRCPanels neededEcho time after
1 in0.82081.49 s
2 in11641.50 s
4 in1.151421.49 s
Panel counts scale with volume.
RoomSizeVolumeEcho time nowPanels needed
Small75 × 45 × 24 ft81,000 ft³6.35 s89
Typical100 × 60 × 24 ft144,000 ft³7.18 s164
Large150 × 90 × 26 ft351,000 ft³8.73 s418

These are estimates for speech frequencies (500–1,000 Hz). Use the room calculator with your own measurements, then load the result into the designer.